Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks
Lumecon LWP-FT-HO High Output Forward Throw Wall Pack Print E-mail

LUMECON ETD™ SYSTEM: 
The Lumecon High Output LED Light engine utilizes the Lumecon ETD™ (Enhanced Thermal Dissipation) System. The ETD System Engines are thermally bonded to provide maximum thermal dissipation to the exterior of the fixture to ensure long life. To protect the light engine panel from moisture and corrosion, the complete face of the LED light engine panel is uniformly coated with a UV stabilized acrylic polymer resin that meets MIL and ASTM dielectric standards and UL and IPC standards for flammability, moisture resistance and thermal shock.

LED LIGHT COLOR / QUALITY:
The High Output LEDs come in a standard 4,700K Neutral White, with an available option of 3,250K Warm White or 6,250K Cool White on the Kelvin temperature scale. All are rated for a minimum of 90,000 hours of continuous operation at ambient temperatures from -40°F (-40°C) to 95°F (+35°C).

HOUSING:
Die-cast aluminum housing and hinged top, textured architectural bronze powder coat finish over a chromate conversion coating.

LENS:
Molded prismatic borosilicate glass lens.

ELECTRICAL:
The LED power supply is UL Class 2 rated and RoHS compliant. It automatically accepts any input voltage from 120VAC to 277VAC and also features optional 0-10V dimming inputs. The power supply has a related lifetime of 100,000 hours under normal operating conditions and ambient air temperatures of 77ºF or less. Additional options include button photocell, inline fuse and 10kV surge suppressor.

BATTERY BACK-UP:
When normal power fails, the emergency driver, which works in conjunction with the AC LED driver, immediately switches into emergency mode, operating the LEDs for a code-compliant 90 minutes. When AC power is restored, the driver automatically returns to charging mode. This is a UL Recognized component, and meets all applicable safety standards.

SPLIT CIRCUIT EMERGENCY EGRESS (Optional):
The split-circuit wiring consists of two independent circuits of LEDs that allow for one of the circuits to be fed by a remote emergency backup power source separate from the main supply.

OCCUPANCY SENSOR (Optional):
Outdoor motion sensors provide occupancy based control of outdoor lighting. Raintight and rated for -40°F to 130°F, sensors perform reliably in all weather conditions. Available with on/off or dim/high functionality.

ETL Listed to UL 1598 / 8750 for Wet Locations

*Meets Buy American requirements within the ARRA

Voltage:

1 – 120v
2 – 277v
3 – 347v – 480v

For all available options see LWP-FT Cut Sheet

Download the LWP-FT-HO - Forward Throw Wall Pack Cut Sheet (rev. 10.8.2013) (PDF Format)

Download Photometric Results in an IES File Format

 

Search

Contact Us

Lumecon, LLC.
23107 Commerce Drive

Farmington Hills, MI 48335

(248) 477-5169 Fax
(877) 564-3133 Toll Free
(248) 477-5009 Office


General Information
info@lumecon.com
Sales Information
sales@lumecon.com

Associations

           dlc

imsa logo  ida logo 1

apwa logo

ies logo

ite logo

Copyright © 2010 Lumecon. All Rights Reserved.
Administrator | FTP Manager








RocketTheme Joomla Templates