Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks
Lumecon LWP2 - Forward Throw Wall Pack

LED LIGHT COLOR / QUALITY:
The High Output LEDs range from 5,500K to 6,300K Cool White with an available option of 3,000 to 3,700K Warm White on the Kelvin temperature scale. Both are rated for a minimum of 110,000 hours of continuous operation at ambient  temperatures from -40°F (-40°C) to 95°F (+35°C).

HOUSING:
Die-cast aluminum housing and hinged top, textured architectural bronze  powder coat finish over a chromate conversion coating.

LENS:
Molded prismatic borosilicate glass lens.

MOUNTING:
Cast-in template for mounting directly over a 4” recessed outlet box, or use 1/2” surface.

ELECTRICAL:
Each constant current power supply (LED driver) is UL8750 recognized, CE certified to EN61347-1 and -2-13, and IP67 rated. The drivers are selfswitching to accept any input voltage from 120-277VAC and 50-60Hz frequency range. The driver has built-in  over-voltage and short-circuit protection, and is EN61000-compliant for THD, flicker/fluctuation, burst transients (L4), and RFI (L3). 347-480 Volt transformer available at an additional cost.

BATTERY BACK-UP (Remote only optional):
When normal power fails, the emergency driver, which works in conjunction with the AC LED driver, immediately switches into emergency mode, operating the LEDs for a code-compliant 90 minutes. When AC power is restored, the driver automatically returns to charging mode. This is a UL Recognized component, and meets all applicable safety standards.

SPLIT CIRCUIT EMERGENCY EGRESS (Optional):
The split-circuit wiring consists of two independent circuits of LEDs that allow for one of the circuits to be fed by a remote emergency backup power source separate from the main supply.

OCCUPANCY SENSOR (Optional):
Outdoor motion sensors provide occupancy based control of outdoor lighting. Raintight and rated for -40°F to 130°F, sensors perform reliably in all weather conditions.

LED WATTAGE:
33w

LUMEN OUTPUT:
1694.2 lumens

Voltage:
1 – 120v – 277v
3 – 347v – 480v

Options:
BB- Battery Back-up
BBCD – Battery Back-up Cold
OC – Occupancy Sensor
SCEE – Split Circuit Emergency Egress

UL and cUL Listed for Wet Locations.

PATENT NUMBER(S):
5,857,767


Download the LWP2 - Forward Throw Wall Pack Cut Sheet (rev. 2011.6.9) (PDF Format)

Download Photometric Results in an IES File Format
 
Copyright © 2010 Lumecon. All Rights Reserved.