Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks
Lumecon LFL2 - Large Area Flood Light

LED LIGHT COLOR / QUALITY:
The High Output LEDs range from 5,500K to 6,300K  Cool White with an available option of 3,000 to 3,700K Warm White on the Kelvin temperature scale. Both are rated for a minimum of 110,000 hours of continuous operation at ambient temperatures from -40°F (-40°C) to 95°F (+35°C).

HOUSING:
Die-cast aluminum housing, front frame & ballast box with bronze powdercoat finish over a chromate conversion coating. Housing swivels from 0° to 30°, & includes angle indicators at adjustment points.

LENS:
Tempered glass lens.

MOUNTING:
Easy-Hang Wall bracket (Included); allows one-person mounting! Optional Pole Mount brackets for one to four fixtures as well as a two-piece swivel bracket are available.

ELECTRICAL:
Each constant current power supply (LED driver) is UL8750 recognized, CE certified to EN61347-1 and -2-13, and IP67 rated.  The drivers are self-switching to accept any input voltage from 120-277VAC and 50-60Hz frequency range.  The driver has built-in over-voltage and short-circuit protection, and is EN61000-compliant for THD, flicker/fluctuation, burst transients (L4), and RFI (L3). 347-480 Volt transformer available at an additional cost.

BATTERY BACK-UP (Optional):
When normal power fails, the emergency driver, which works in conjunction with the AC LED driver, immediately switch into emergency mode, operating the LEDs for a code-compliant 90 minutes. When AC power is restored, the driver automatically returns to the charging mode. This unit is UL Component Recognized and CSA Certified.

BATTERY BACK-UP COLD (Optional):
Cold Emergency LED Driver for extended temperatures (-20°C to +60°C) operates a lighting load for a minimum of 90 minutes in emergency mode. This unit is UL Component Recognized and CSA Certified.

SPILT CIRCUIT EMERGENCY EGRESS (Optional):
The split-circuit wiring consists of two independent circuits of LEDs that allow for one of the circuits to be fed by a remote emergency backup power source separate from the main supply.

OCCUPANCY SENSOR (Optional):
Outdoor motion sensors provide occupancy based control of outdoor lighting. Raintight and rated for -40°F to 130°F, EW sensors perform reliably in all weather conditions.

UL and cUL Listed for Wet Locations.

PATENT NUMBER(S):
5,857,767

Voltage:
1 – 120v – 277v
3 – 347v – 480v

Options:
BB- Battery Back-up
BBCD – BatteryBack-up Cold
OC – Occupancy Sensor
SCEE – Split Circuit Emergency Egress


Download the LFL2 -Large Area Flood Light (rev. 10.26) (PDF Format)

Download Photometric Results in an IES File Format

 
Copyright © 2010 Lumecon. All Rights Reserved.
Administrator | FTP Manager








RocketTheme Joomla Templates